Skip to content

PMF_a092 — Xtal Oscillator

Full alert identifier: PMF_a092_xtalOscillator

Message shown in the car

Powertrain issue detected - Schedule service Issue may persist even if functionality is restored

Alert description

Pedal Monitor Warning: Crystal oscillator inactive.

Potential impact

Unit may have limited torque or torque disablement with this alert present, see other active alerts for more details.

Set condition

This condition is at application boot when the external crystal is not the active clock source.

Clear condition

This alert does not clear for the duration of the power on cycle once set.

Signals to check

These diagnostic fields are associated with PMF_a092. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Pll Clock Source PMF_a092_pllClockSource
0
INTOSC2
1
XTAL
2
INTOSC1
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PMF_a092.