Skip to content

PMF_a006 — Under Torque Check

Full alert identifier: PMF_a006_underTorqueCheck

Alert description

Pedal Monitor Warning: DI torque actual does not match PM torque measured

Potential impact

No immediate impact.

Set condition

Set when absolute difference between DIx_torqueActual and PMx_torqueMeasured is > 100Nm for 100ms

Clear condition

This alert will clear 1s after torque difference is below threshold

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Motor RPM PMF_a006_motorRPM RPM
Torque Actual PMF_a006_torqueActual
-4096
SNA
Nm
Torque Measured PMF_a006_torqueMeasured
-4096
SNA
Nm

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PMF_a006.

Browse all PMF alert codes