PCS_a047 — Bootloader Crc Mismatch
Full alert identifier: PCS_a047_bootloaderCrcMismatch
Alert description
PCS detects that at least one bootloader has mismatched CRC
Potential impact
Inability to update, inability to boot AC charger
Set condition
Power conversion system application detects that calculated bootloader CRC is unexpected
Clear condition
Power conversion system detects that bootloader CRC matches expected value
Signals to check
These diagnostic fields are associated with PCS_a047. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Calculated Bootloader Crc
PCS_
|
— |
Cpu 1 Boot Loader Crc Mismatch
PCS_
|
— |
Cpu 2 Boot Loader Crc Mismatch
PCS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a047.