PCS_a020 — Chg Enable Line Mismatch

Full alert identifier: PCS_a020_chgEnableLineMismatch

Alert description

PCS charging hardware enable line does not match CAN signal

Potential impact

Inability to AC charge

Set condition

Charger detects that sensed enable hardline state does not match state reported on CAN for more than five seconds

Clear condition

Charger detects that sensed enable hardline state matches state reported on CAN for more than one second

Signals to check

These diagnostic fields are associated with PCS_a020. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Charge Enable Can PCS_a020_chargeEnableCan —
Charge Enable Line PCS_a020_chargeEnableLine —