PCS_a020 — Chg Enable Line Mismatch
Full alert identifier: PCS_a020_chgEnableLineMismatch
Alert description
PCS charging hardware enable line does not match CAN signal
Potential impact
Inability to AC charge
Set condition
Charger detects that sensed enable hardline state does not match state reported on CAN for more than five seconds
Clear condition
Charger detects that sensed enable hardline state matches state reported on CAN for more than one second
Signals to check
These diagnostic fields are associated with PCS_a020. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Charge Enable Can
PCS_
|
— |
Charge Enable Line
PCS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a020.