PCS_a016 — Chg All Phases Faulted
Full alert identifier: PCS_a016_chgAllPhasesFaulted
Message shown in the car
Cannot charge - Poor grid power quality possible Retry / Try other charge location or Supercharging
Alert description
All charger phases are faulted, not able to deliver power to the battery pack
Potential impact
Inability to AC charge
Set condition
All charger phases are faulted and retries are exhausted
Clear condition
Charge cable is removed or inserted or battery management system issues clear fault request
Signals to check
These diagnostic fields are associated with PCS_a016. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ph A Volt Src Missing Detected
PCS_
|
— |
Ph B Volt Src Missing Detected
PCS_
|
— |
Ph C Volt Src Missing Detected
PCS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a016.