Skip to content

HVP_w067 — Hvil Cal Node Mismatch

Full alert identifier: HVP_w067_HvilCalNodeMismatch

Message shown in the car

Vehicle configuration mismatch Service is required

Alert description

The High Voltage Interlock Loop (HVIL) type in the High Voltage Processor's (HVP) calibration block or firmware file does not match the expected configuration.

Potential impact

Contactors will open and may remain open while not in the drive state.

Set condition

The HVIL type determined by the HVP is mismatched with the numberHVILNodes gateway configuration.

Clear condition

The HVIL type determined by the HVP matches with the numberHVILNodes gateway configuration.

Signals to check

These diagnostic fields are associated with HVP_w067. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Hvil Type From Gateway HVP_a067_hvilTypeFromGateway
0
UNKNOWN
1
LV
2
CAN
—
Hvil Type From Hvp HVP_a067_hvilTypeFromHvp
0
UNKNOWN
1
LV
2
CAN
—
Hvil Type Is From Cal HVP_a067_hvilTypeIsFromCal —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVP_w067.

Browse all HVP alert codes