HVP_w026 — Hvil Fault
Full alert identifier: HVP_w026_HvilFault
Alert description
Sets if an HVIL fault is detected. Contactors cannot close (car will no longer drive) if the contactors are currently open. If no repairs were performed and the alert clears on its own, there is risk of reoccurrence.
Potential impact
Contactors will not close, it may open if vehicle not in drive
Set condition
The HVIL is broken or HVIL nodes are lower than expected
Clear condition
The HVIL is intact
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Dif Voltage
HVP_
|
V |
Dir Voltage
HVP_
|
V |
Input Voltage
HVP_
|
V |
Internal Voltage
HVP_
|
V |
Output Voltage
HVP_
|
V |
| Signal | Unit |
|---|---|
Hvil Status
HVP_
|
— |
Check other alerts