Skip to content

HVP_w060 — Stack Voltage Sense

Full alert identifier: HVP_w060_StackVoltageSense

Alert description

Indicates a mismatch between a Battery Monitoring Board (BMB) stack voltage and the sum of its brick voltages

Potential impact

Other BMB voltage signals will be substituted given that voltage sensing is unreliable

Set condition

Any BMB has a difference between the stack voltage and the sum of its brick voltages that has deviated outside the in-bounds threshold

Clear condition

All BMB stack voltages are within the in-bounds threshold of the sum of their brick voltages

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Stack Voltage HVP_a060_stackVoltage V
Sum Brick Voltage HVP_a060_sumBrickVoltage V
Signal Unit
Stack Id HVP_a060_stackId —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVP_w060.

Browse all HVP alert codes