HVP_w010 — Under Voltage Fault
Full alert identifier: HVP_w010_UnderVoltageFault
Alert description
A brick voltage is below minimum voltage limit
Potential impact
The conactors may open immdediately or pyro fuse may blow
Set condition
A brick voltage is below minimum voltage limit for X duration (in seconds)
Clear condition
All brick voltages are above minimum voltage limit
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Brick Voltage
HVP_
|
V |
| Signal | Unit |
|---|---|
Brick Id
HVP_
|
— |
Primary Chain Sensor
HVP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVP_w010.