HVP_w025 — Ver Supply Fault
Full alert identifier: HVP_w025_VerSupplyFault
Alert description
Warns if the Energy reserve voltage supply is below minimum voltage threshold
Potential impact
The pyro diagnostics may fail, the contactors will not close
Set condition
The Energy reserve voltage supply is below minimum voltage threshold
Clear condition
The Energy reserve voltage supply is above minimum voltage threshold
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Pack Voltage
HVP_
|
V |
Voltage 1
HVP_
|
V |
Voltage 2
HVP_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVP_w025.