FC_a276 — GB neg To Pcb Delta Lo
Full alert identifier: FC_a276_GB_negToPcbDeltaLo
Alert description
The Fast Charge (FC) Electronic Control Unit (ECU) has detected a temperature gap between negative pin and Printed Circuit Board (PCB) below -40deg centigrade, limiting the Direct Current (DC) charge limit to 60A.
Potential impact
DC charge current is limited to 60A.
Set condition
FC ECU has detected a temperature gap lower than -40deg centigrade negative pin and PCB.
Clear condition
Unplug charge handle.
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of FC_a276.