Skip to content

EPAS3P_a074 — Over Heat Protect

Full alert identifier: EPAS3P_a074_overHeatProtect

Alert description

Electronic Power Assisted Steering (EPAS) module Overheat Protection (OHP) is active.

Potential impact

Steering assist is reduced and External Angle Control (EAC) is degraded.

Set condition

OHP limit reports a value less than 140A.

Clear condition

OHP limit reports a value greater than or equal to 140A.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPAS3P_a074.

Browse all EPAS3P alert codes