EPAS3P_a160 — Latent Fault Test Result
Full alert identifier: EPAS3P_a160_latentFaultTestResult
Alert description
Secondary EPAS initialization self test failed
Potential impact
Secondary EPAS initialization issue detected. Redundant power steering unavailable
Set condition
Electronic Power Assist Steering (EPAS) detected an issue in power electronics hardware
Clear condition
Electronic Power Assist Steering (EPAS) power cycle. Alert latches after setting
Signals to check
These diagnostic fields are associated with EPAS3P_a160. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Current Sensor Status
EPAS3P_
|
— |
Gate Driver Status
EPAS3P_
|
— |
Gate Drvr Init Test
EPAS3P_
|
— |
High Side Disconnect Fet Status
EPAS3P_
|
— |
Hsd Fet Fail Short Test
EPAS3P_
|
— |
Inv Fet Init Test
EPAS3P_
|
— |
Inverter Fet Status
EPAS3P_
|
— |
Latent Fault Test Timeout
EPAS3P_
|
— |
Show 3 more fields
| Signal | Unit |
|---|---|
Pha Disconn Fail Open Test
EPAS3P_
|
— |
Pha Disconn Fail Short Test
EPAS3P_
|
— |
Phase Disconnect Fet Status
EPAS3P_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPAS3P_a160.