Skip to content

DIRER_a041 — Sdc MIA

Full alert identifier: DIRER_a041_sdcMIA

Alert description

Drive Inverter Warning: The Secondary Disconnect Controller (SDC) is not communicating to the Drive Inverter (DI), or there is an interface version mismatch. Service is needed.

Potential impact

The Secondary Disconnect Controller (SDC) may not be monitoring potential drive unit failures.

Set condition

The Secondary Disconnect Controller (SDC) is not communicating to the Drive Inverter (DI), or there is a mismatch between their interface version.

Clear condition

The SDC resumes communication to DI and their interface versions match.

Signals to check

These diagnostic fields are associated with DIRER_a041. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
SDC Status MIA DIRER_a041_SDC_status_MIA —
Di Uart Rx Version DIRER_a041_diUartRxVersion —
Sdc Uart Rx Version DIRER_a041_sdcUartRxVersion —
Uart Rx Data Available DIRER_a041_uartRxDataAvailable —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIRER_a041.

Browse all DIRER alert codes