Skip to content

DIREL_a002 — Hw Phase Bgate Drive

Full alert identifier: DIREL_a002_hwPhaseBgateDrive

Alert description

The Drive Inverter (DIx) has detected a condition affecting functionality at the gate driver on Phase B.

Potential impact

DIx may be inoperable.

Set condition

DIx has detected a condition affecting functionality at the gate driver on Phase B. View payload signal to confirm reason for alert.

Clear condition

DIx no longer detects a condition affecting functionality at the gate driver on Phase B.

Signals to check

These diagnostic fields are associated with DIREL_a002. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Asynch Stop H DIREL_a002_asynchStop_H —
Asynch Stop L DIREL_a002_asynchStop_L —
Deadtime Error H DIREL_a002_deadtimeError_H —
Deadtime Error L DIREL_a002_deadtimeError_L —
Desat H DIREL_a002_desat_H —
Desat L DIREL_a002_desat_L —
Fault Line 1 Gpio H DIREL_a002_faultLine1Gpio_H —
Fault Line 1 Gpio L DIREL_a002_faultLine1Gpio_L —
Show 35 more fields
Signal Unit
Gate Drive Err Counter DIREL_a002_gateDriveErrCounter —
Local Comm Error H DIREL_a002_localCommError_H —
Local Comm Error L DIREL_a002_localCommError_L —
Local Reg Error H DIREL_a002_localRegError_H —
Local Reg Error L DIREL_a002_localRegError_L —
Local Reset H DIREL_a002_localReset_H —
Local Reset L DIREL_a002_localReset_L —
Overvolt VDD H DIREL_a002_overvoltVDD_H —
Overvolt VDD L DIREL_a002_overvoltVDD_L —
Overvolt VH H DIREL_a002_overvoltVH_H —
Overvolt VH L DIREL_a002_overvoltVH_L —
Overvolt VL H DIREL_a002_overvoltVL_H —
Overvolt VL L DIREL_a002_overvoltVL_L —
Remote Comm Error H DIREL_a002_remoteCommError_H —
Remote Comm Error L DIREL_a002_remoteCommError_L —
Remote Reg Error H DIREL_a002_remoteRegError_H —
Remote Reg Error L DIREL_a002_remoteRegError_L —
Remote Reset H DIREL_a002_remoteReset_H —
Remote Reset L DIREL_a002_remoteReset_L —
Sense H DIREL_a002_sense_H —
Sense L DIREL_a002_sense_L —
Spi Error H DIREL_a002_spiError_H —
Spi Error L DIREL_a002_spiError_L —
Thermal Shutdown H DIREL_a002_thermalShutdown_H —
Thermal Shutdown L DIREL_a002_thermalShutdown_L —
Thermal Warning H DIREL_a002_thermalWarning_H —
Thermal Warning L DIREL_a002_thermalWarning_L —
Undervolt VCC H DIREL_a002_undervoltVCC_H —
Undervolt VCC L DIREL_a002_undervoltVCC_L —
Undervolt VDD H DIREL_a002_undervoltVDD_H —
Undervolt VDD L DIREL_a002_undervoltVDD_L —
Undervolt VH H DIREL_a002_undervoltVH_H —
Undervolt VH L DIREL_a002_undervoltVH_L —
Undervolt VL H DIREL_a002_undervoltVL_H —
Undervolt VL L DIREL_a002_undervoltVL_L —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIREL_a002.

Browse all DIREL alert codes