CP_a154 — Ac Charging Stopped OT

Full alert identifier: CP_a154_acChargingStoppedOT

Alert description

The charge port inlet pin temperature has reached an unacceptable level (greatly exceeds normal operating range), causing AC charging to stop.

Potential impact

AC charging will be interrupted and remain unavailable until a charge cable cycle occurs (disconnect and reconnect) and the charge port inlet pin temperature returns to normal operating range.

Set condition

The charge port inlet pin temperature reaches a level where it is unacceptable to continue AC charging (temperature detected greatly exceeds normal operating range).

Clear condition

The charge cable is disconnected from the charge port inlet. Note: Alert will continue to set until the charge port inlet pin temperature is detected within normal operating range.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Ac Pin Temp 1 CP_a154_acPinTemp1
255
SNA
C
Ac Pin Temp 2 CP_a154_acPinTemp2
255
SNA
C
Ac Pin Temp Velocity CP_a154_acPinTempVelocity
511
SNA
C/min
Ambient Temp CP_a154_ambientTemp C
Pcs Line Charge Current CP_a154_pcsLineChargeCurrent A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a154.

Browse all CP alert codes