Skip to content

CP_a153 — Thermal Ac Limit Active

Full alert identifier: CP_a153_thermalAcLimitActive

Alert description

The charge port inlet pin temperature has reached a level where limiting AC charge current is necessary until temperature returns to normal operating range.

Potential impact

AC charge current is limited.

Set condition

The charge port inlet pin temperature reaches an unexpected level (temperature detected exceeds normal operating range).

Clear condition

The charge port inlet pin temperature returns to an acceptable level (within normal operating range).

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Ac Pin Temp 1 CP_a153_acPinTemp1
255
SNA
C
Ac Pin Temp 2 CP_a153_acPinTemp2
255
SNA
C
Ac Pin Temp Velocity CP_a153_acPinTempVelocity
511
SNA
C/min
Ambient Temp CP_a153_ambientTemp C
Pcs Line Charge Current CP_a153_pcsLineChargeCurrent A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a153.

Browse all CP alert codes