CP_a110 — Thermal Velocity High
Full alert identifier: CP_a110_thermalVelocityHigh
Message shown in the car
Charge port requires service Charging may be unavailable
Alert description
The charge port (CP) electronic control unit (ECU) detects an unexpected rapid rise in temperature.
Potential impact
DC charging is terminated and is blocked until the charge cable is disconnected.
Set condition
The CP ECU detects that thermal velocity, which is calculated each minute, exceeds the expected increase rate of temperature.
Clear condition
The charge cable is disconnected.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Thermal Velocity
CP_
|
C/min |
Thermistor Temp
CP_
|
C |
| Signal | Unit |
|---|---|
Thermistor Id
CP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a110.