Skip to content

CP_a110 — Thermal Velocity High

Full alert identifier: CP_a110_thermalVelocityHigh

Message shown in the car

Charge port requires service Charging may be unavailable

Alert description

The charge port (CP) electronic control unit (ECU) detects an unexpected rapid rise in temperature.

Potential impact

DC charging is terminated and is blocked until the charge cable is disconnected.

Set condition

The CP ECU detects that thermal velocity, which is calculated each minute, exceeds the expected increase rate of temperature.

Clear condition

The charge cable is disconnected.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Thermal Velocity CP_a110_thermalVelocity
511
SNA
C/min
Thermistor Temp CP_a110_thermistorTemp C
Signal Unit
Thermistor Id CP_a110_thermistorId —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a110.

Browse all CP alert codes