Skip to content

CP_a131 — Evse Comm Timeout

Full alert identifier: CP_a131_evseCommTimeout

Message shown in the car

Charging session was not started in time Disconnect charge cable - Then connect and retry

Alert description

Communication times out between the charge port (CP) electronic control unit (ECU) and the electric vehicle supply equipment (EVSE).

Potential impact

Charging does not start.

Set condition

The EVSE and the CP ECU cannot establish communication within the set timeframe between being connected and starting to charge.

Clear condition

The charge port (CP) electronic control unit (ECU) detects that the charge cable was disconnected.

Signals to check

These diagnostic fields are associated with CP_a131. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Power Transfer Protocol CP_a131_powerTransferProtocol
0
NO CHARGE
1
AC CHARGE
2
SUPERCHARGER
3
CCS DC
4
CCS AC
5
GBDC
6
CHADEMO
7
V2X
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a131.

Browse all CP alert codes