CP_a072 — V2g Evcc Timeout
Full alert identifier: CP_a072_v2gEvccTimeout
Alert description
The charge port (CP) electronic control unit (ECU) detects that the charging session is taking longer to startup than expected and exceeds the maximum time frame.
Potential impact
CCS charging may not start or may be interrupted.
Set condition
The charging session does not start within the expected time frame.
Clear condition
The charge cable is removed or communication with the EVSE stops.
Signals to check
These diagnostic fields are associated with CP_a072. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Cable Check Expired
CP_
|
— |
Comms Setup Expired
CP_
|
— |
Current Message
CP_
|
— |
Pre Charge Expired
CP_
|
— |
Ready To Charge Expired
CP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a072.