Skip to content

CP_a125 — Unexpected LV Juice State

Full alert identifier: CP_a125_unexpectedLVJuiceState

Alert description

The charge port (CP) electronic control unit detects that it unexpectedly does not have permission to use high power from the low voltage (LV) bus.

Potential impact

The CP latch, door, and inlet heater do not behave as expected.

Set condition

The CP ECU detects that it does not have permission to use high power from the LV bus.

Clear condition

The CP ECU detects that it has permission to use high power from the LV bus.

Signals to check

These diagnostic fields are associated with CP_a125. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Ok To Use High Power CP_a125_okToUseHighPower —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a125.

Browse all CP alert codes