CP_a066 — Prox Latched Idle Pilot
Full alert identifier: CP_a066_proxLatchedIdlePilot
Message shown in the car
Charging equipment not ready See equipment instructions to start charging
Alert description
Control pilot signal remains in state B1, indicating the charge station is connected to the vehicle but is not ready to charge the vehicle, for too long while a charge cable is plugged into the charge port (CP). Charging may not start or may be interrupted unexpectedly.
Potential impact
Charging may not start or may be interrupted unexpectedly.
Set condition
Charge handle proximity is detected as connected to the charge port (CP) without charge handle button pressed, and control pilot signal is detected in state B1 for more than five seconds.
Clear condition
Charge handle proximity is no longer detected as connected to the charge port (CP) without charge handle button pressed, or control pilot signal is no longer detected in state B1. Clears after five seconds if either of these conditions is true and a charge cable is still present. Otherwise, clears immediately.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Pilot High
CP_
|
V |
Pilot Low
CP_
|
V |
| Signal | Unit |
|---|---|
Proximity
CP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a066.