Skip to content

CC_a013 — Veh Conn OT

Full alert identifier: CC_a013_vehConnOT

Message shown in the car

Unable to charge - Charge handle too hot Check charge handle or charge port for debris

Alert description

Wall connector charge handle temperature too high.

Potential impact

Wall connector will reduce reported current capability in 25 percent increments until condition clears, or current reaches 0 and charging is stopped.

Set condition

Wall connector charge handle temperature exceeds 78 degC.

Clear condition

Wall connector charge handle temperature falls below 58 degC or user interaction if charging was stopped.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Handle Temp CC_a013_handleTemp DegC

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_a013.

Browse all CC alert codes