Skip to content

CC_a012 — Wall Plug OT

Full alert identifier: CC_a012_wallPlugOT

Message shown in the car

Unable to charge - Wall connection too hot Outlet or Wall Connector wiring must be checked

Alert description

Wall connector input wiring temperature is too high.

Potential impact

Wall connector will reduce reported current capability in 25 percent increments until condition clears, or current reaches 0 and charging is stopped.

Set condition

Wall connector input wiring temperature exceeds 100 degC.

Clear condition

Wall connector input wiring temperature falls below 80 degC or user interaction if charging was stopped.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Input Thermopile CC_a012_inputThermopile V
Input Thermopile Dvdt CC_a012_inputThermopileDvdt V/sec

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_a012.

Browse all CC alert codes