Skip to content

BMS_d257 — Internal Isolation Fault

Full alert identifier: BMS_d257_internalIsolationFault

Alert description

The Battery Management System (BMS) has detected multiple times that the HV isolation is lower than the threshold while the pack contactors are open.

Potential impact

Vehicle is unable to start, charge or support the low voltage system.

Set condition

The BMS detects the HV isolation value dropped below the minimum threshold when the pack contactors are open.

Clear condition

This information is not available in the alert reference.

Diagnostic trouble code (DTC)

P0E7400

Hybrid/EV Battery Voltage Internal Isolation Fault

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_d257.

Browse all BMS alert codes