BMS_a077 — SW Charger Regulation
Full alert identifier: BMS_a077_SW_Charger_Regulation
Alert description
The Battery Management System (BMS) has stopped charging because the maximum brick voltage within the High Voltage (HV) battery or the charge current exceeded the target values for too long.
Potential impact
Charging is temporarily unavailable.
Set condition
While charging, the maximum brick voltage or charge current exceeded the target value for too long.
Clear condition
The BMS reports the brick voltage or charge current is less than the maximum target value and charging ends.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Max Brick V
BMS_
|
V |
Max Brick V Target
BMS_
|
V |
Pack Current
BMS_
|
A |
Pack Target Current
BMS_
|
A |
| Signal | Unit |
|---|---|
Charge Err Type
BMS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_a077.