BMS_a030 — Impedance Deviation
Full alert identifier: BMS_a030_Impedance_Deviation
Alert description
High impedance was detected on one or more bricks.
Potential impact
One or more cells in a brick are likely missing, resulting in a high impedance current path. Other potential causes are a high Direct Current Resistance (DCR), intermittent anode laser weld on the given brick(s), or an islanded brick.
Set condition
Impedance for one or more bricks exceeds the noise threshold for several measurement counts.
Clear condition
All bricks have impedance measurements within the noise threshold.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Fault Threshold
BMS_
|
Ratio |
Max Brick Impedance
BMS_
|
mOhm |
Max Normalized Impedance Dev
BMS_
|
Ratio |
Worst Brick Soc
BMS_
|
PCT |
| Signal | Unit |
|---|---|
Num Bricks
BMS_
|
— |
Worst Brick ID
BMS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_a030.