BMS_a030 — Impedance Deviation

Full alert identifier: BMS_a030_Impedance_Deviation

Alert description

High impedance was detected on one or more bricks.

Potential impact

One or more cells in a brick are likely missing, resulting in a high impedance current path. Other potential causes are a high Direct Current Resistance (DCR), intermittent anode laser weld on the given brick(s), or an islanded brick.

Set condition

Impedance for one or more bricks exceeds the noise threshold for several measurement counts.

Clear condition

All bricks have impedance measurements within the noise threshold.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Fault Threshold BMS_a030_faultThreshold Ratio
Max Brick Impedance BMS_a030_maxBrickImpedance mOhm
Max Normalized Impedance Dev BMS_a030_maxNormalizedImpedanceDev Ratio
Worst Brick Soc BMS_a030_worstBrickSoc PCT
Signal Unit
Num Bricks BMS_a030_numBricks —
Worst Brick ID BMS_a030_worstBrickID —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_a030.

Browse all BMS alert codes