BCFDM_a116 — Door Config Error
Full alert identifier: BCFDM_a116_DoorConfigError
Alert description
The door controller's left or right side configuration is invalid or unspecified.
Potential impact
Door controller may not communicate and will not operate as expected. Run the correct 'Side Learn' action to configure it.
Set condition
Door controller side configuration is not set, invalid, or cannot be determined by reading the dedicated harness pins. Alert payload data should provide more information on the specific condition(s) involved.
Clear condition
The door controller's left or right side configuration is valid and correctly set.
Signals to check
These diagnostic fields are associated with BCFDM_a116. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Genealogy Invalid Data
BCFDM_
|
— |
Genealogy Read Error
BCFDM_
|
— |
Genlgy Harness Mismatch
BCFDM_
|
— |
Harness Invalid Data
BCFDM_
|
— |
Harness Read Error
BCFDM_
|
— |
Side Not Configured
BCFDM_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BCFDM_a116.