BCFALCP_a276 — Unexpected USS Status
Full alert identifier: BCFALCP_a276_unexpectedUSSStatus
Alert description
The ultrasonic controller used by the Falcon doors is reported as OFF, or as FAULTED, while it is expected to be ON
Potential impact
The Falcon door ultrasonic sensors might not be powered on, which could limit the door obstacle detection capabilities
Set condition
The ultrasonic controller used by the Falcon door is reported as OFF, or as FAULTED, for more than 500 milliseconds
Clear condition
The Falcon door ultrasonic controller is reported as ON
Signals to check
These diagnostic fields are associated with BCFALCP_a276. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ultrasonic System Status
BCFALCP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BCFALCP_a276.