Skip to content
Model X

BCFALCP_a089 — Unexpected Stop

Full alert identifier: BCFALCP_a089_UnexpectedStop

Alert description

The Falcon door controller detects the door stops unexpectedly while moving to the requested position.

Potential impact

The Falcon door will not reach the requested position.

Set condition

The Falcon door stops unexpectedly while moving to the requested position. Alert log signal data should provide more information on the specific condition detected.

Clear condition

The Falcon door controller receives a new door movement request.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Lower Current In Cycle BCFALCP_a089_LowerCurrentInCycle A
Lower Door Angle BCFALCP_a089_LowerDoorAngle deg
Upper Current In Cycle BCFALCP_a089_UpperCurrentInCycle A
Upper Door Angle BCFALCP_a089_UpperDoorAngle deg
Upper Actuator Temp BCFALCP_a089_upperActuatorTemp A
Signal Unit
Door Request Source BCFALCP_a089_DoorRequestSource —
Last Falcon SM State BCFALCP_a089_LastFalconSMState —
Latch Status BCFALCP_a089_LatchStatus —
Open To Fit BCFALCP_a089_OpenToFit —
Stopping Condition BCFALCP_a089_StoppingCondition —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BCFALCP_a089.

Browse all BCFALCP alert codes