BCFALCD_a276 — Unexpected USS Status

Full alert identifier: BCFALCD_a276_unexpectedUSSStatus

Alert description

The ultrasonic controller used by the Falcon doors is reported as OFF, or as FAULTED, while it is expected to be ON

Potential impact

The Falcon door ultrasonic sensors might not be powered on, which could limit the door obstacle detection capabilities

Set condition

The ultrasonic controller used by the Falcon door is reported as OFF, or as FAULTED, for more than 500 milliseconds

Clear condition

The Falcon door ultrasonic controller is reported as ON

Signals to check

These diagnostic fields are associated with BCFALCD_a276. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Ultrasonic System Status BCFALCD_a276_ultrasonicSystemStatus
0
ON
1
OFF
2
FAULTED
3
BLOCKED
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BCFALCD_a276.