Skip to content

BCFALCD_a173 — Lower Rear Over Temp

Full alert identifier: BCFALCD_a173_lowerRearOverTemp

Alert description

The Falcon Door Body Controller has estimated section actuator temperatures exceeding 100.0 deg C (212 deg F).

Potential impact

Continued movement of the door while the section actuator is overheating can cause damage and lead to automatic shutdown of door motion. Movement commands are ignored until actuators have cooled.

Set condition

Section actuator temperature model has exceeded 100.0 deg C (212 deg F).

Clear condition

Section actuator model estimate has cooled down to a temperature of 85.0 deg C (185.0 deg F).

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BCFALCD_a173.

Browse all BCFALCD alert codes