Skip to content
Model X

BCFALCD_a144 — Upper Front Cur Limit

Full alert identifier: BCFALCD_a144_upperFrontCurLimit

Alert description

The Falcon Door Body Controller has detected the upper front actuator experienced a current limit surge lasting for over 100 milliseconds. The electric current flowing through the motor surpassed normal operating limits for a short period of time.

Potential impact

Actuator may experience reduced performance if operating past its current limit for prolonged periods of time.

Set condition

The upper front actuator experienced a current limit surge lasting for over 100 milliseconds and exceeding 19A.

Clear condition

Upper rear actuator operates within normal current limits without experiencing any surges.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Current Limit BCFALCD_a144_currentLimit A
Over Current Time Ms BCFALCD_a144_overCurrentTimeMs INTEGRAL
Upper Door Angle BCFALCD_a144_upperDoorAngle deg
Upper Front Max Curren BCFALCD_a144_upperFrontMaxCurren A
Upper Rear Max Current BCFALCD_a144_upperRearMaxCurrent A
Signal Unit
Falcon State BCFALCD_a144_falconState —
Is Calibrated BCFALCD_a144_isCalibrated —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BCFALCD_a144.

Browse all BCFALCD alert codes