- TAS_a001 — Watchdog Reset TAS_a001_WatchdogReset Warns if the processor has experienced a reset due to watchdog reset.
- TAS_a002 — Power Loss Reset TAS_a002_PowerLossReset Tesla Air Suspension (TAS) has detected an unplanned processor reset caused by power loss.
- TAS_a003 — SW Assertion TAS_a003_SWAssertion Tesla Air Suspension (TAS) has detected an internal software assertion failure.
- TAS_a012 — CPU Reset TAS_a012_CPUReset Tesla Air Suspension (TAS) has detected an initiated CPU reset triggered by error conditions.
- TAS_a015 — NVMM Error TAS_a015_NVMMError An issue is indicated from the non-volatile memory manager.
- TAS_a016 — NVMM Record Error TAS_a016_NVMMRecordError An issue is indicated from a particular non-volatile memory record.
- TAS_a021 — Task Scheduler Error TAS_a021_TaskSchedulerError If a task was not able to run at the appropriate time.
- TAS_a022 — Task Init Error TAS_a022_TaskInitError If a task failed to initialize.
- TAS_a025 — Crash Event TAS_a025_CrashEvent Air suspension functionality is disabled due to vehicle crash reported by restraint module.
- TAS_a030 — PW Merror FL TAS_a030_PWMerrorFL Abnormal Pulse Width Modulation (PWM) signal received from front left PWM height sensor.
- TAS_a031 — PW Merror FR TAS_a031_PWMerrorFR Abnormal Pulse Width Modulation (PWM) signal received from front right PWM height sensor.
- TAS_a032 — PW Merror RL TAS_a032_PWMerrorRL Abnormal Pulse Width Modulation (PWM) signal received from rear left PWM height sensor.
- TAS_a033 — PW Merror RR TAS_a033_PWMerrorRR Abnormal Pulse Width Modulation (PWM) signal received from rear right PWM height sensor.
- TAS_a034 — PW Mshort FL TAS_a034_PWMshortFL Signal line from front left PWM height sensor shorted to ground.
- TAS_a035 — PW Mshort FR TAS_a035_PWMshortFR Signal line from front right PWM height sensor shorted to ground.
- TAS_a036 — PW Mshort RL TAS_a036_PWMshortRL Signal line from rear left PWM height sensor shorted to ground.
- TAS_a037 — PW Mshort RR TAS_a037_PWMshortRR Signal line from rear right PWM height sensor shorted to ground.
- TAS_a038 — PW Mopen FL TAS_a038_PWMopenFL Front left height sensor disconnected, or signal line from front left Pulse Width Modulation (PWM) height sensor floating.
- TAS_a039 — PW Mopen FR TAS_a039_PWMopenFR Front right height sensor disconnected, or signal line from front right Pulse Width Modulation (PWM) height sensor floating.
- TAS_a040 — PW Mopen RL TAS_a040_PWMopenRL Rear left height sensor disconnected, or signal line from rear left Pulse Width Modulation (PWM) height sensor floating.
- TAS_a041 — PW Mopen RR TAS_a041_PWMopenRR Rear right height sensor disconnected, or signal line from rear right Pulse Width Modulation (PWM) height sensor floating.
- TAS_a043 — Task1ms Error TAS_a043_Task1msError Debug information for 1ms task errors. Set along with TaskSchedulerError.
- TAS_a044 — Task10ms Error TAS_a044_Task10msError Debug information for 10ms task errors. Set along with TaskSchedulerError.
- TAS_a045 — Task100ms Error TAS_a045_Task100msError Debug information for 100ms task errors. Set along with TaskSchedulerError.
- TAS_a046 — Task1000ms Error TAS_a046_Task1000msError Debug information for 1000ms task errors. Set along with TaskSchedulerError.
- TAS_a061 — X CP Connected TAS_a061_XCPConnected Indicates an active connection to the XCP state machine
- TAS_a062 — X CP Was Connected TAS_a062_XCPWasConnected Indicates there was an active connection to the XCP state machine
- TAS_a063 — Abort Fault TAS_a063_abortFault Indicates there was a data abort fault reported on the ECU.
- TAS_a064 — Abort Fault Ext TAS_a064_abortFaultExt Indicates there was a data abort fault reported on the ECU.
- TAS_a065 — Ahb Write Fault TAS_a065_ahbWriteFault Indicates there was a fault reported on an AHB bus due to attempted write on a protected region.
- TAS_a070 — Under Voltage12 V TAS_a070_underVoltage12V Supply voltage to ECU is below 8.5V
- TAS_a071 — Over Voltage12 V TAS_a071_overVoltage12V Supply voltage to ECU is above 16.5V
- TAS_a072 — Short Circuit5 V On Board TAS_a072_shortCircuit5VOnBoard On board 5V switched supply is measured to be approximately 0V.
- TAS_a073 — Under Voltage5 V On Board TAS_a073_underVoltage5VOnBoard On board 5V switched supply is measured to be below 4.5V.
- TAS_a074 — Short Circuit5 V Off Board TAS_a074_shortCircuit5VOffBoard Off board 5V switched supply is measured to be approximately 0V.
- TAS_a075 — Under Voltage5 V Off Board TAS_a075_underVoltage5VOffBoard Off board 5V switched supply is measured to be under 4.5V.
- TAS_a076 — Over Voltage5 V Off Board TAS_a076_overVoltage5VOffBoard Off board 5V switched supply is measured to be over 5.5V.
- TAS_a077 — Pressure Sig V Too Low TAS_a077_pressureSigVTooLow Pressure sensor signal voltage too low; likely disconnected.
- TAS_a078 — Pressure Sig V Too High TAS_a078_pressureSigVTooHigh Pressure sensor signal voltage too high.
- TAS_a080 — Short Circuit5 V Height TAS_a080_shortCircuit5VHeight Off board 5V ride height sensor switched supply is measured to be approximately 0V.
- TAS_a081 — Under Voltage5 V Height TAS_a081_underVoltage5VHeight Off board 5V ride height sensor switched supply is measured to be under 4.5V.
- TAS_a082 — Over Voltage5 V Height TAS_a082_overVoltage5VHeight Off board 5V ride height sensor switched supply is measured to be over 5.5V.
- TAS_a083 — Short Circuit5 V Analog TAS_a083_shortCircuit5VAnalog Off board 5V pressure sensor switched supply is measured to be approximately 0V.
- TAS_a084 — Under Voltage5 V Analog TAS_a084_underVoltage5VAnalog Off board 5V pressure sensor switched supply is measured to be under 4.5V.
- TAS_a085 — Over Voltage5 V Analog TAS_a085_overVoltage5VAnalog Off board 5V pressure sensor switched supply is measured to be over 5.5V.
- TAS_a086 — Under Voltage12 V Swtchd TAS_a086_underVoltage12VSwtchd Switched 12V supply measured considerably lower than input 12V supply.
- TAS_a087 — Over Voltage12 V Swtchd TAS_a087_overVoltage12VSwtchd Switched 12V supply measured considerably higher than input 12V supply.
- TAS_a093 — OTP Error TAS_a093_OTPError The one time programmable memory driver has encountered an error.
- TAS_a094 — DAS MIA TAS_a094_DAS_MIA One or more CAN messages from DAS are not being received by the ECU.
- TAS_a095 — DIS MIA TAS_a095_DIS_MIA One or more CAN messages from DIS are not being received by the ECU.