iBooster brake booster alerts
Browse 256 IBST alert codes and open an entry for its description and recorded conditions.
IBST alert codes
Showing 51–100 of 256
- IBST_a051 — Ecu Bandgap IBST_a051_ecuBandgap iBooster (IBST) detected and Electronic Control Unit (ECU) bandgap failure.
- IBST_a052 — Adc Pin Test IBST_a052_AdcPinTest iBooster (IBST) Analog-to-Digital Converter (ADC) pin test detected an open ADC pin.
- IBST_a053 — Adc Selftest C5 P IBST_a053_AdcSelftestC5P iBooster (IBST) Analog-to-Digital Converter (ADC) self test C5P detected a failure.
- IBST_a054 — Adc Peripheral Fault IBST_a054_AdcPeripheralFault iBooster (IBST) detected a condition in the Analog-to-Digital Converter (ADC) peripheral.
- IBST_a055 — UB6 Supply Path Fault IBST_a055_UB6SupplyPathFault iBooster (IBST) detected high ohmic UB6 path (a large deviation between UB6 & UBB during motor actuation).
- IBST_a056 — UB6 Plausi Mon Fault IBST_a056_UB6PlausiMonFault iBooster (IBST) detected a UB6 to UBB plausi voltage divider drift failure (large deviation in the UB6 to UBB ratio).
- IBST_a057 — Micro Register Fault IBST_a057_microRegisterFault iBooster (IBST) detected an Analog-to-Digital Converter (ADC) register bit has flipped or is stuck.
- IBST_a058 — NvM Write Cycle Exceed IBST_a058_NvMWriteCycleExceed iBooster (IBST) detected a failure word event where write/erase service was requested sporadically.
- IBST_a059 — NvM Eeprom Size IBST_a059_NvMEepromSize iBooster (IBST) detected a failure word where Electrically Erasable Programmable Read-Only Memory (EEPROM) size detection failed or EEPROM size does not match configured size and actual size mounted on layout.
- IBST_a060 — NvM Migration Fault IBST_a060_NvMMigrationFault iBooster (IBST) detected a migration process failure due to power interruption in previous power cycle or a migration was not possible due to insufficient space available on Electrically Erasable Programmable Read-Only Memory (EEPROM).
- IBST_a061 — Asw System Time Out IBST_a061_AswSystemTimeOut iBooster (IBST) detected the ASW configuration took too long
- IBST_a062 — MICB6 Transfer Error IBST_a062_MICB6TransferError iBooster (IBST) detected Serial Peripheral Interface (SPI) transfer to TLE9180 bridge driver Application-Specific Integrated Circuit (ASIC) has failed (error frame wrong address or timeout CSIH error).
- IBST_a063 — Temp Sens2 Short To Supply IBST_a063_tempSens2ShortToSupply iBooster (IBST) detected Brushless Motor (BLM) temperature sensor 2 line shorted to supply.
- IBST_a064 — Temp Sens1 Short To Ground IBST_a064_tempSens1ShortToGround iBooster (IBST) detected Brushless Motor (BLM) temperature sensor 1 line shorted to ground.
- IBST_a065 — Temp Sens2 Short To Ground IBST_a065_tempSens2ShortToGround iBooster (IBST) detected Brushless Motor (BLM) temperature sensor 2 line shorted to ground.
- IBST_a066 — Temp Sens1 Short To Supply IBST_a066_tempSens1ShortToSupply iBooster (IBST) detected Brushless Motor (BLM) temperature sensor 1 line shorted to supply.
- IBST_a067 — Temp Sens Implaus Voltage IBST_a067_tempSensImplausVoltage iBooster (IBST) detected Brushless Motor (BLM) temperature sensors are not plausible voltage values.
- IBST_a068 — Charge Pump Undervoltage IBST_a068_chargePumpUndervoltage iBooster (IBST) detected charge Pump Tests/Monitor could not be executed due to an undervoltage condition.
- IBST_a069 — Greasing Routine Fault IBST_a069_greasingRoutineFault iBooster (IBST) detected backward bound could not be detected during greasing routine, resulting in a time out.
- IBST_a070 — Not Shut Down NvM Write IBST_a070_notShutDownNvMWrite NvM Item 'Not_ShutDown_Right' can not be written
- IBST_a071 — Not Shut Down NvM Read IBST_a071_notShutDownNvMRead NvM Item 'Not_ShutDown_Right' is not readable
- IBST_a072 — Not Shut Down Right IBST_a072_notShutDownRight iBooster was not shutdown right
- IBST_a073 — Jump In Adjust NvM Read IBST_a073_jumpInAdjustNvMRead iBooster (IBST) detected Non-volatile Memory (NvM) value for the GapLap JI-Adjust is not readable.
- IBST_a074 — Find Idle Data NvM Write IBST_a074_FindIdleDataNvMWrite iBooster (IBST) detected find idle data can not be written in the find idle calibration routine in plant/service (Rotation Position Sensor (RPS) angle at backward bound and idle and lips IDs).
- IBST_a075 — Find Idle Routine Fault IBST_a075_FindIdleRoutineFault iBooster (IBST) detected the find idle routine in plant failed.
- IBST_a076 — Master Cyl Length Read IBST_a076_masterCylLengthRead iBooster (IBST) read failed failure for parameter MasterCylinderLength.
- IBST_a077 — Run Out Motor Saturated IBST_a077_runOutMotorSaturated Indicates IBST pRunout brake pressure was not reached due to motor torque output saturation.
- IBST_a078 — Wear Offset Comp NVM Read IBST_a078_wearOffsetCompNVMRead iBooster (IBST) wear offset value not able to read from Non-volatile Memory (NVM).
- IBST_a079 — Motor Temp High Level1 IBST_a079_motorTempHighLevel1 iBooster (IBST) firmware set in case of temperature degradation level 1.
- IBST_a080 — Motor Temp High Level2 IBST_a080_motorTempHighLevel2 iBooster (IBST) firmware set in case of temperature degradation level 2.
- IBST_a081 — Travel Deviation IBST_a081_travelDeviation iBooster (IBST) detected differential travel is permanently not compensated.
- IBST_a082 — Motor Speed Deviation IBST_a082_motorSpeedDeviation iBooster (IBST) detected a permanent deviation between the target speed and the actual motor speed.
- IBST_a083 — Spindle Position Too High IBST_a083_spindlePositionTooHigh iBooster (IBST) detected spindle position value is higher than the physical limited values.
- IBST_a084 — CAN Transceiver HW Fault IBST_a084_CANTransceiverHWFault iBooster (IBST) Controller Area Network (CAN)-Driver: Timeout caused by Hardware (HW)-Error (CAN-Controller configuration failed).
- IBST_a085 — Supply Undervoltage Lvl3 IBST_a085_supplyUndervoltageLvl3 iBooster (IBST) detected UBB supply voltage is below shutdown threshold (undervoltage level 3).
- IBST_a086 — Supply Overvoltage Lvl3 IBST_a086_supplyOvervoltageLvl3 iBooster (IBST) detected UBB voltage is above shutdown threshold (overvoltage level 3).
- IBST_a087 — Rotor Sin Out Of Range Low IBST_a087_rotorSinOutOfRangeLow iBooster (IBST) detected Rotation Position Sensor (RPS) Sin+ or Sin- signal too low.
- IBST_a088 — Rotor Cos Out Of Range Low IBST_a088_rotorCosOutOfRangeLow iBooster (IBST) detected Rotation Position Sensor (RPS) Cos+ or Cos-signal too low.
- IBST_a089 — Rotor Sin Out Of Range High IBST_a089_rotorSinOutOfRangeHigh iBooster (IBST) detected Rotation Position Sensor (RPS) Sin+ or Sin-signal too high.
- IBST_a090 — Rotor Cos Out Of Range High IBST_a090_rotorCosOutOfRangeHigh iBooster (IBST) detected Rotation Position Sensor (RPS) Cos+ or Cos-signal too high.
- IBST_a091 — SMM One Requests Init IBST_a091_SMMOneRequestsInit iBooster (IBST) detected an SMM information failure.
- IBST_a092 — System Start Time Out IBST_a092_systemStartTimeOut iBooster (IBST) detected maximum allowed time to start the system has been reached.
- IBST_a093 — UEXS Overtemperature IBST_a093_UEXSOvertemperature iBooster (IBST) detected an ECU output (UEXS) over-temperature condition and has been switched off.
- IBST_a094 — XPASS Echo Time Deviation IBST_a094_XPASSEchoTimeDeviation iBooster (IBST) detected data reception did not complete within the expected time interval.
- IBST_a095 — XPASS Time Out IBST_a095_XPASSTimeOut iBooster (IBST) detected data reception did not complete within the expected time interval.
- IBST_a096 — Bridge Driver Mon Error IBST_a096_bridgeDriverMonError iBooster (IBST) detected an application-specific integrated circuit (ASIC) internal error.
- IBST_a097 — Bridge Driver Error IBST_a097_bridgeDriverError iBooster (IBST) detected an application-specific integrated circuit (ASIC) internal error.
- IBST_a098 — Bridge Shorted Phase IBST_a098_bridgeShortedPhase iBooster (IBST) detected a bridge metal-oxide-semiconductor field-effect transistor (MOSFET) shorted error.
- IBST_a099 — Bridge Switch Init Error IBST_a099_bridgeSwitchInitError iBooster (IBST) detected a failure in the metal-oxide-semiconductor field-effect transistor (MOSFET) bridge driver supply switch.
- IBST_a100 — Current2 Offset High IBST_a100_current2OffsetHigh iBooster (IBST) detected offset current 2 out of range (high).