Rear drive inverter alerts
Browse 189 DIR alert codes and open an entry for its description and recorded conditions.
DIR alert codes
Showing 151–189 of 189
- DIR_a240 — Clear Fuses Routine DIR_a240_clearFusesRoutine This alert indicates the fuse clearing routine was attempted.
- DIR_a241 — System Thermally Limited DIR_a241_systemThermallyLimited Drive Inverter Warning: Report current limited due to thermal temperatures for diagnostic purpose
- DIR_a242 — Spin Down Learning DIR_a242_spinDownLearning Drive unit spindown learning calibration routine is in progress.
- DIR_a243 — Ecu Log Available DIR_a243_ecuLogAvailable Triggers ODIN service to upload log buffer
- DIR_a244 — Mech Safe State Applied DIR_a244_mechSafeStateApplied Alert for software trigger of mechanical safe state two-phase disconnect device.
- DIR_a245 — Mech Safe State Pre Warn DIR_a245_mechSafeStatePreWarn Diagnostic alert for new unarmed software triggers of mechanical two phase open
- DIR_a246 — Recovery At Speed Error DIR_a246_recoveryAtSpeedError The Drive Interface (DI) detects the at-speed recovery mechanism encountered an error.
- DIR_a247 — Rotor Offset Error DIR_a247_rotorOffsetError The Drive Interface (DI) detects the rotor is irrationally offset.
- DIR_a248 — Vehicle Speed Limited DIR_a248_vehicleSpeedLimited The Drive Inverter (DIx) detects the heat sink temperature sensor is irrational. The motor speed and vehicle speed may be limited.
- DIR_a249 — High Stator Temp From Resist DIR_a249_highStatorTempFromResist High estimated stator temperature from resistance
- DIR_a250 — Preregulator Rail DIR_a250_preregulatorRail Preregulator rail voltage out of spec
- DIR_a251 — Oil Pump Service DIR_a251_oilPumpService Drive Inverter Warning: Oil pump service
- DIR_a252 — Current Core Fallback DIR_a252_currentCoreFallback Current sensor calibration invalid
- DIR_a253 — Lv Boosted Rail DIR_a253_lvBoostedRail The Drive Inverter (DIx) detects the Low Voltage (LV) boosted rail voltage is out of specification.
- DIR_a254 — Active Discharge Rail DIR_a254_activeDischargeRail LV boosted rail voltage out of spec
- DIR_a255 — Current Gain Fallback DIR_a255_currentGainFallback Current sensor gains invalid
- DIR_d085 — Drive Inverter Board Failure DIR_d085_driveInverterBoardFailure The Drive Inverter (DI) has detected a condition with the board due to a switch short.
- DIR_d089 — Invalid Torque Command DIR_d089_invalidTorqueCommand The Drive Inverter (DI) has detected a Signal Not Available (SNA) or invalid torque command.
- DIR_d104 — Reset Unintended DIR_d104_resetUnintended The Drive Inverter (DI) has detected an unintended reset.
- DIR_d105 — Bus Voltage Sensor Issue DIR_d105_busVoltageSensorIssue The Drive Inverter (DI) has detected an irrational bus voltage sensor reading.
- DIR_d118 — Oil Pump Comms Lost DIR_d118_oilPumpCommsLost The Drive Inverter (DI) has detected a communication loss with the oil pump.
- DIR_d124 — Oil Pump Service Required DIR_d124_oilPumpServiceRequired The Drive Inverter (DI) has detected a low gearbox fluid pressure.
- DIR_d125 — Current Sensor Issue DIR_d125_currentSensorIssue The Drive Inverter (DI) has detected an invalid or unavailable current sensor data.
- DIR_d129 — Oil Pump Issue DIR_d129_oilPumpIssue The Drive Inverter (DI) has detected an issue with the oil pump.
- DIR_d130 — Position Sensor Issue DIR_d130_positionSensorIssue The Drive Inverter (DI) has detected an irrational position sensor reading.
- DIR_d131 — Current Sensor Offset DIR_d131_currentSensorOffset The Drive Inverter (DI) has detected the current sensor offset exceeded the expected range. There may also be a current imbalance detected in the 3 phases of the drive inverter.
- DIR_d132 — Bus UV Issue DIR_d132_busUVIssue The Drive Inverter (DI) has detected an invalid bus voltage sensor output.
- DIR_d135 — Rotated Stator DIR_d135_rotatedStator The Drive Inverter (DI) has detected a rotated stator.
- DIR_d137 — Current Sensor Out Of Range DIR_d137_currentSensorOutOfRange The Drive Inverter (DI) has detected current sensor readings that are out of range.
- DIR_d138 — Inverter LV Power Supply Low DIR_d138_inverterLVPowerSupplyLow The Drive Inverter (DI) has detected that the Low Voltage (LV) power supply is low.
- DIR_d141 — Cooling System Issue DIR_d141_coolingSystemIssue The Drive Inverter (DI) has detected a condition with the cooling system or the coolant flow.
- DIR_d143 — Wheel Speed Correlation Issue DIR_d143_wheelSpeedCorrelationIssue The Drive Inverter (DI) has detected an issue with the wheel speed and motor speed correlation.
- DIR_d163 — Recoverable Overcurrent DIR_d163_recoverableOvercurrent The Drive Inverter (DI) has detected a recoverable overcurrent event.
- DIR_d164 — Firmware Config Mismatch DIR_d164_firmwareConfigMismatch The Drive Inverter (DI) has detected a software incompatibility.
- DIR_d165 — Stator Over Temperature DIR_d165_statorOverTemperature The Drive Inverter (DI) has detected overtemperature issues with the stator.
- DIR_d166 — Rotor Over Temperature DIR_d166_rotorOverTemperature The Drive Inverter (DI) has detected overtemperature issues with the rotor.
- DIR_d167 — Temp Sensor Issue DIR_d167_tempSensorIssue The Drive Inverter (DI) has detected irrational data from the temperature sensor.
- DIR_d175 — Oil Pump B Comms Lost DIR_d175_oilPumpBCommsLost The Drive Inverter (DI) has detected a communication loss with the oil pump.
- DIR_d179 — Oil Pump B Issue DIR_d179_oilPumpBIssue The Drive Inverter (DI) has detected a condition affecting oil pump B.