VCFRONT_a269 — Drve Blckd Vltge Too Low2
Full alert identifier: VCFRONT_a269_drveBlckdVltgeTooLow2
Alert description
The vehicle cannot enter Drive state because the measured LV battery voltage is too low. This alert is intended to capture the LV battery conditions when drive blocking is activated and assist with diagnosis if primary alert drveBlckdVltgeTooLow cannot be logged by the vehicle Gateway (GTW) at time of initial occurrence due to LV undervoltage condition.
Potential impact
While this alert is primarily informational and intended for logging purposes, the vehicle may be unable to drive, or may take longer than expected to enter Drive state.
Set condition
The measured LV battery voltage dropped below the level required for the drive state for 0.5 seconds, and vehicle GTW is reported as available for logging.
Clear condition
Clears automatically after 10 seconds.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
IBS Amp Hours
VCFRONT_
|
Ah |
IBS Current
VCFRONT_
|
A |
IBS Voltage
VCFRONT_
|
V |
LV Battery Temp
VCFRONT_
|
degC |
| Signal | Unit |
|---|---|
Vehicle Power State
VCFRONT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a269.