Skip to content

VCFRONT2_a286 — Recirc Exv Fault

Full alert identifier: VCFRONT2_a286_recircExvFault

Alert description

The vehicle controller detects the recirculation electronic expansion valve (EXV) motor driver is reporting an electrical condition (short or disconnect).

Potential impact

Cabin climate control system air conditioning and heating may be limited or unavailable. Powertrain performance may be limited.

Set condition

The recirculation EXV motor driver is reporting an electrical condition (short or disconnect).

Clear condition

The recirculation EXV motor driver no longer reports an electrical condition (short or disconnect).

Signals to check

These diagnostic fields are associated with VCFRONT2_a286. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Charge Pump Undervoltage VCFRONT2_a286_chargePumpUndervoltage —
Driver Has Comm Error VCFRONT2_a286_driverHasCommError —
Driver State VCFRONT2_a286_driverState —
Driver Therm Shutdown VCFRONT2_a286_driverThermShutdown —
Driver Therm Warn VCFRONT2_a286_driverThermWarn —
Is Coil Open X VCFRONT2_a286_isCoilOpenX —
Is Coil Open Y VCFRONT2_a286_isCoilOpenY —
Is Coil Short XN Gnd VCFRONT2_a286_isCoilShortXNGnd —
Show 8 more fields
Signal Unit
Is Coil Short XN Vbb VCFRONT2_a286_isCoilShortXNVbb —
Is Coil Short XP Gnd VCFRONT2_a286_isCoilShortXPGnd —
Is Coil Short XP Vbb VCFRONT2_a286_isCoilShortXPVbb —
Is Coil Short YN Gnd VCFRONT2_a286_isCoilShortYNGnd —
Is Coil Short YN Vbb VCFRONT2_a286_isCoilShortYNVbb —
Is Coil Short YP Gnd VCFRONT2_a286_isCoilShortYPGnd —
Is Coil Short YP Vbb VCFRONT2_a286_isCoilShortYPVbb —
Undervoltage VCFRONT2_a286_undervoltage —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT2_a286.

Browse all VCFRONT2 alert codes