Skip to content

VCFRONT2_a142 — Exv Motor Fault

Full alert identifier: VCFRONT2_a142_exvMotorFault

Alert description

The front vehicle controller (VCFRONT) detects the chiller electronic expansion valve (EXV) motor driver is experiencing an electrical condition (short or disconnect).

Potential impact

Cabin climate control system air conditioning may be limited or unavailable. Powertrain performance may be limited.

Set condition

The chiller EXV motor driver is experiencing an electrical condition (short or disconnect).

Clear condition

The chiller EXV motor driver no longer experiences an electrical condition (short or disconnect).

Signals to check

These diagnostic fields are associated with VCFRONT2_a142. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Charge Pump Undervoltage VCFRONT2_a142_chargePumpUndervoltage —
Driver Has Comm Error VCFRONT2_a142_driverHasCommError —
Driver State VCFRONT2_a142_driverState —
Driver Therm Shutdown VCFRONT2_a142_driverThermShutdown —
Driver Therm Warn VCFRONT2_a142_driverThermWarn —
Is Coil Open X VCFRONT2_a142_isCoilOpenX —
Is Coil Open Y VCFRONT2_a142_isCoilOpenY —
Is Coil Short XN Gnd VCFRONT2_a142_isCoilShortXNGnd —
Show 8 more fields
Signal Unit
Is Coil Short XN Vbb VCFRONT2_a142_isCoilShortXNVbb —
Is Coil Short XP Gnd VCFRONT2_a142_isCoilShortXPGnd —
Is Coil Short XP Vbb VCFRONT2_a142_isCoilShortXPVbb —
Is Coil Short YN Gnd VCFRONT2_a142_isCoilShortYNGnd —
Is Coil Short YN Vbb VCFRONT2_a142_isCoilShortYNVbb —
Is Coil Short YP Gnd VCFRONT2_a142_isCoilShortYPGnd —
Is Coil Short YP Vbb VCFRONT2_a142_isCoilShortYPVbb —
Undervoltage VCFRONT2_a142_undervoltage —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT2_a142.

Browse all VCFRONT2 alert codes