Skip to content

VCFRONT1_a509 — eFuse AS IC Manager State Mismatch

Full alert identifier: VCFRONT1_a509_eFuseASICManagerStateMismatch

Alert description

The eFuse application-specific integrated circuit (ASIC) on the vehicle controller is in an unexpected state

Potential impact

Vehicle Controller eFuse ASIC may not turn on or off as expected

Set condition

Vehicle controller eFuse ASIC is not in the requested state

Clear condition

Vehicle Controller eFuse ASIC is back in the unlocked state or has been retried

Signals to check

These diagnostic fields are associated with VCFRONT1_a509. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Channel VCFRONT1_a509_channel
0
INVALID
1
EPAS2
2
RIGHT CONTROLLER
3
PCS
4
AUTOPILOT 2
5
BRAKE MOTOR ECU 2
6
BRIDGE
—
Expected State VCFRONT1_a509_expectedState
0
UNKNOWN
1
STANDBY
2
WAKEUP
3
CONFIGURATION
4
UNLOCKED
5
LOCKED
6
SELF TEST PREP
7
SELF TEST
—
Hardware Lockout VCFRONT1_a509_hardwareLockout —
State VCFRONT1_a509_state
0
UNKNOWN
1
STANDBY
2
WAKEUP
3
CONFIGURATION
4
UNLOCKED
5
LOCKED
6
SELF TEST PREP
7
SELF TEST
—
Unlocks Remaining VCFRONT1_a509_unlocksRemaining —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT1_a509.

Browse all VCFRONT1 alert codes