Skip to content

VCFRONT1_a266 — EPAS2 Voltage Mismatch

Full alert identifier: VCFRONT1_a266_EPAS2VoltageMismatch

Alert description

The vehicle controller detects there is voltage mismatch greater than 0.5V between the input power to the front vehicle controller (VCFRONT) and the secondary power steering circuit for the primary Electronic Power Assisted Steering (EPAS2) electronic control unit (ECU).

Potential impact

Power steering may be limited or unavailable.

Set condition

The voltage mismatch is greater than 0.5V between the VCFRONT printed circuit board assembly (PCBA) input voltage and the eFuse output voltage.

Clear condition

The voltage mismatch is less than 0.5V between the VCFRONT printed circuit board assembly (PCBA) input voltage and the eFuse output voltage.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
E Fuse Voltage VCFRONT1_a266_eFuseVoltage V
Vbat Prot Voltage VCFRONT1_a266_vbatProtVoltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT1_a266.

Browse all VCFRONT1 alert codes