Skip to content

VCFRONT1_a204 — Undervoltage Loadshed Triggered

Full alert identifier: VCFRONT1_a204_undervoltageLoadshedTriggered

Alert description

Undervoltage loadshed protection initiated on the Front Vehicle Controller (VCFRONT). Low Voltage (LV) bridge is expected to be open until the protection clears.

Potential impact

LV bridge is open. Impacted loads unavailable in Drive.

Set condition

The 16V bus reports an undervoltage condition on VCFRONT while the vehicle is in Drive.

Clear condition

Undervoltage loadshed protection resets when the vehicle is parked and the 16V bus voltage exceeds 10V.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Pcs Bridge Current VCFRONT1_a204_pcsBridgeCurrent A
Vbus Voltage VCFRONT1_a204_vbusVoltage V
Signal Unit
B Rail Locked VCFRONT1_a204_BRailLocked —
Uv Loadshed Fault Inject VCFRONT1_a204_uvLoadshedFaultInject —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT1_a204.

Browse all VCFRONT1 alert codes