VCFRONT1_a191 — Exit Drive Domain Down
Full alert identifier: VCFRONT1_a191_exitDriveDomainDown
Message shown in the car
Electrical system power reduced Vehicle shutting down
Alert description
A condition with the Low Voltage (LV) system requires the vehicle to come to a stop immediately. The vehicle is entering a graceful power-off (GPO) to exit drive. One or more alerts will be present to indicate that condition.
Potential impact
The vehicle will not enter drive. If the vehicle is driving, it will exit drive through graceful power-off (GPO) to come to a stop immediately. A separate alert should be present to indicate the GPO
Set condition
The Low Voltage (LV) bridge is open (no current flow), and the Vehicle Battery Controller (VCBATT) is unavailable (or MIA).
Clear condition
The Low Voltage (LV) bridge is closed, or the Vehicle Battery Controller (VCBATT) is no longer unavailable (or MIA).
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Bus Voltage
VCFRONT1_
|
V |
| Signal | Unit |
|---|---|
Not Enough Power For Support
VCFRONT1_
|
— |
Bms State
VCFRONT1_
|
— |
Exit Drive Warning Timer Expired
VCFRONT1_
|
— |
Frunk Open
VCFRONT1_
|
— |
Hv State
VCFRONT1_
|
— |
Service Mode
VCFRONT1_
|
— |
Vehicle Power State
VCFRONT1_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT1_a191.