VCBATT2_a306 — Frunk Pri Under Current
Full alert identifier: VCBATT2_a306_frunkPriUnderCurrent
Alert description
The front vehicle controller (VCFRONT) detects the front trunk (also known as the frunk) primary latch is experiencing an undercurrent condition.
Potential impact
The frunk primary latch may be disconnected.
Set condition
The frunk primary latch draws less current than expected.
Clear condition
The frunk primary latch stops actuating or draws current within the expected range.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Actuator Current
VCBATT2_
|
A |
Temperature
VCBATT2_
|
degC |
Voltage
VCBATT2_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT2_a306.