Skip to content

VCBATT2_a305 — Frunk Pri Over Current

Full alert identifier: VCBATT2_a305_frunkPriOverCurrent

Alert description

The front vehicle controller (VCFRONT) detects the front trunk (also known as the frunk) primary latch is experiencing an overcurrent condition, which may prevent the frunk from opening when commanded.

Potential impact

The frunk may not open.

Set condition

The frunk primary latch draws more current than expected.

Clear condition

The frunk primary latch stops actuating or draws current within the expected range.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Actuator Current VCBATT2_a305_actuatorCurrent A
Temperature VCBATT2_a305_temperature degC
Voltage VCBATT2_a305_voltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT2_a305.

Browse all VCBATT2 alert codes