VCBATT1_a415 — Undervoltage Self Test Stuck Off

Full alert identifier: VCBATT1_a415_undervoltageSelfTestStuckOff

Alert description

One or more loads did not turn on during the Battery Domain Undervoltage self-test. Those loads will not be powered while in Drive.

Potential impact

Impacted loads will not be usable in Drive.

Set condition

One or more loads did not turn on during the Battery Domain Undervoltage self-test.

Clear condition

The Battery Domain Undervoltage self-test runs again and the load turns on successfully.

Signals to check

These diagnostic fields are associated with VCBATT1_a415. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Upstream E Fuse Stuck Off VCBATT1_a415_upstreamEFuseStuckOff —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT1_a415.