VCBATT1_a165 — Unxpctd eFuse Lckout
Full alert identifier: VCBATT1_a165_unxpctdEFuseLckout
Message shown in the car
Vehicle will consume more energy while idle Schedule service
Alert description
The battery vehicle controller (VCBATT) detects an eFuse lockout is active (via voltage measurement of the lockout circuit) when the front vehicle controller (VCFRONT) is not reporting an eFuse lockout is active.
Potential impact
If the eFuse lockout circuit is enabled unexpectedly, VCBATT cannot enable or disable the low voltage (LV) power feed to other controllers. Vehicle features and functions relying on power supply via VCBATT may be unavailable. Vehicle software updates may not complete successfully.
Set condition
The VCBATT detects voltage on the eFuse lockout circuit (nominal 5V on eFuse lockout circuit for 2 seconds) when VCFRONT has not reported the lockout circuit as active.
Clear condition
The VCBATT eFuse lockout circuit voltage measurement indicates an eFuse lockout is no longer active, and the VCFRONT is not reporting an active eFuse lockout.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Lockout Voltage
VCBATT1_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT1_a165.