Skip to content

RCU_a006 — Wake Line Open

Full alert identifier: RCU_a006_wakeLineOpen

Alert description

RCU Low Voltage (LV) state CAN signal from Front Vehicle Controller (VCFRONT) reports LV is on while the wake line voltage is off.

Potential impact

The RCU may not power on or shut down correctly.

Set condition

VCFRONT RCU LV state signal VCFRONT_iBoosterLVState is received as LV_ON while the hardwired wake line (RCU connector pin 4) is off for more than 2 minutes while there is no power supply hard undervoltage.

Clear condition

Clears when VCFRONT RCU LV state signal matches hardwired wake line state at the start of the next power cycle.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of RCU_a006.

Browse all RCU alert codes