Skip to content

PCS2_a159 — Dcdc Gdps Health Check Failed

Full alert identifier: PCS2_a159_dcdcGdpsHealthCheckFailed

Alert description

The Power Conversion System (PCS) has failed the self-performed Gate Drive Power Supply (GDPS) health check on DCDC converter.

Potential impact

Low voltage (LV) Regulation, DC charging, regenerative braking, and discharge functionality may be limited or paused.

Set condition

The PCS ECU does not pass the self-performed GDPS health check on DCDC converter.

Clear condition

The DCDC converter GDPS health check passes.

Signals to check

These diagnostic fields are associated with PCS2_a159. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
HVDC Gdps Health Status PCS2_a159_HVDCGdpsHealthStatus
0
UNDETERMINED
1
HEALTHY
2
UNHEALTHY POWER RAIL UV
3
UNHEALTHY ISOTEMPSENSE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a159.

Browse all PCS2 alert codes