Skip to content

PCS2_a136 — Cyclo A Mosfet Health Check Failed

Full alert identifier: PCS2_a136_cycloAMosfetHealthCheckFailed

Alert description

The Power Conversion System (PCS2) self-performed MOSFET health check is unsuccessful on Cyclo Converter A

Potential impact

AC Charging may be limited or unavailable.

Set condition

The PCS2 ECU does not pass the self-performed MOSFET health check on Cyclo Converter A

Clear condition

Cyclo Converter A MOSFET health check passes

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Measured Resonant Frequency PCS2_a136_measuredResonantFrequency kHz
Signal Unit
Ac Voltage Present PCS2_a136_acVoltagePresent —
Dcac Enable Line Deasserted PCS2_a136_dcacEnableLineDeasserted —
Failed Sequence PCS2_a136_failedSequence —
Hv Bus Voltage Trip Has Occurred PCS2_a136_hvBusVoltageTripHasOccurred —
Hvdc Over Current Trip Has Occurred PCS2_a136_hvdcOverCurrentTripHasOccurred —
Line Over Current Trip Has Occurred PCS2_a136_lineOverCurrentTripHasOccurred —
Line Over Voltage Trip Has Occurred PCS2_a136_lineOverVoltageTripHasOccurred —
Lv Bus Voltage Trip Has Occurred PCS2_a136_lvBusVoltageTripHasOccurred —
Show 7 more fields
Signal Unit
Mosfet Index Under Test PCS2_a136_mosfetIndexUnderTest —
Mosfet Leg Under Test PCS2_a136_mosfetLegUnderTest
0
AC LEG 1
1
AC LEG 2
2
AC LEG 3
3
AC LEG N
4
DC LEG 1
5
DC LEG 2
—
Power Rail Trip Has Occurred PCS2_a136_powerRailTripHasOccurred —
Pwm Tripped During Health Check PCS2_a136_pwmTrippedDuringHealthCheck —
Result Exempted PCS2_a136_resultExempted —
Retry Count PCS2_a136_retryCount —
Tank Freq Zero With Edge Detected PCS2_a136_tankFreqZeroWithEdgeDetected —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a136.

Browse all PCS2 alert codes